Service

Back to service catalogue
Galios elektronika Testing

Response-Speed Measurements of Photodetectors and High-Voltage Switches

Power Electronics

Reference
4.2.5
Lead partner
VU

Technical Scope and Capabilities

This service determines response speed of photodetectors and high-voltage switches using 10 ps pulsed excitations at 10 Hz repetition rate and 100 ps temporal resolution.

Excitation wavelengths:

  • 263 nm
  • 351 nm
  • 527 nm
  • 1053 nm.

Core Infrastructure / Tools / Equipment

The service uses a 6 GHz oscilloscope for drift and rise time measurements.

Possible Restrictions

  • Devices can be unbiased or biased up to 5 kV
  • drift or rise times can be measured with up to 100 ps temporal resolution
  • sample size up to 10 × 10 cm
  • adjustable spatial resolution from 0.05 mm to 1 mm
  • samples must be equipped with ohmic contacts.

Wide Bandgap Semiconductors for High-Power and High-Frequency Applications